DrugLib.com — Drug Information Portal

Rx drug information, pharmaceutical research, clinical trials, news, and more



Canister tip orientation and residual volume have significant impact on the dose of benzocaine delivered by Hurricaine spray.

Author(s): Khorasani A, Candido KD, Ghaleb AH, Saatee S, Appavu SK

Affiliation(s): Division of Critical Care Anesthesiology and Department of Anesthesiology & Pain Management, Cook County Hospital, Chicago, IL 60612, USA. arjangk@SPHK.com

Publication date & source: 2001-02, Anesth Analg., 92(2):379-83.

Delivered quantities of 20% benzocaine spray (Hurricaine; Beutlich L.P. Pharmaceuticals, Waukegan, IL) are estimated by counting the number of sprays or the spraying time. Because Hurricaine spray supplies a continuous (albeit nonmetered) stream of benzocaine, neither method addresses delivered dose. We hypothesized that dose per time is a function of canister content and orientation. Thirty full canisters of Hurricaine were placed into three equal orientations (upright, inverted, or horizontal). Extrapolating from a full canister, four different estimates of benzocaine residual volume were determined before spraying out the contents (80%, 60%, 40%, and 20% full). Each canister was then sprayed for 10-s intervals, and the quantity delivered was calculated and compared statistically. Upright canisters 100% full emitted more benzocaine than canisters with residual volume 20% full (190 +/- 10 vs 172 +/- 10 mg/s). Inverted canisters emitted significantly less benzocaine from 100% full to residual volume 20% full (188 +/- 14 vs 70 +/- 10 mg/s). Oriented horizontally, two full canisters emitted <76 mg/s benzocaine, contrasted with the remaining eight in that group (186 +/- 20 mg/s). We conclude that the benzocaine (Hurricaine) sprayed in milligrams per second depends on canister content and orientation. When residual volumes diminish, there is a reduction in spraying volume per time. This diminution occurs progressively from larger to smaller residual volumes with canisters oriented horizontally, inverted, or upright. Arbitrary documentation of spraying time bears no relationship to dose delivered. Perhaps affixing an atomization device to a graduated syringe filled with benzocaine will help increase accuracy and precision in dosing.

Page last updated: 2006-01-31

-- advertisement -- The American Red Cross
 
Home | About Us | Contact Us | Site usage policy | Privacy policy

All Rights reserved - Copyright DrugLib.com, 2006-2017