DrugLib.com — Drug Information Portal

Rx drug information, pharmaceutical research, clinical trials, news, and more



A comparative study of the levonorgestrel-releasing intrauterine system Mirena(R) versus the Copper T380A intrauterine device during lactation: breast-feeding performance, infant growth and infant development.

Author(s): Shaamash AH, Sayed GH, Hussien MM, Shaaban MM

Affiliation(s): Department of Obstetrics and Gynecology, Faculty of Medicine, Assiut University, Assiut, Egypt.

Publication date & source: 2005-11, Contraception., 72(5):346-51. Epub 2005 Jul 6.

BACKGROUND: Mirena(R) is a levonorgestrel-releasing intrauterine system (LNG-IUS) that provides highly effective and long-acting progestogen-only contraception. OBJECTIVE: The objective of this study was to analyze the possible effects of using LNG-20 mug IUS on breast-feeding performance, infant growth and infant development during the first postpartum year as compared with the Copper T380A intrauterine device (Cu T380A IUD). DESIGN: This study is a prospective, controlled and randomized trial. SETTING: The study was conducted at the Department of Obstetrics and Gynecology, Assiut University Hospital, Egypt. METHODS: Three hundred twenty lactating women asking for initiation of contraception during the early postpartum stage were assigned randomly into two groups, the LNG-20 mug IUS group (n=163) and the Cu T380A group (n=157). The insertions were done 6-8 weeks postpartum. Each participant was followed up at three monthly intervals after insertion and until the first birthday of her baby. During these visits, the breast-feeding pattern was assessed, certain infant physical growth parameters were measured and a set of infant development tests was performed. RESULTS: No pregnancy occurred in both groups. There were no significant differences in the net continuation rates between the two groups (89.3 for LNG-IUS vs. 90.9 for Cu T380A). The LNG-20 mug IUS group had comparable rates of breast-feeding continuation, complete weaning, full breast-feeding and partial breast-feeding, with the Cu-IUD group. No statistically significant differences were found between groups with regard to all infant physical growth parameters and various infant development tests. CONCLUSION: The findings of the current study confirm that the use of LNG-20 mug IUS during the first postpartum year in lactating women provides highly effective and acceptable contraception and does not negatively influence breast-feeding or the growth and development of breast-fed infants.

Page last updated: 2006-01-31

-- advertisement -- The American Red Cross
 
Home | About Us | Contact Us | Site usage policy | Privacy policy

All Rights reserved - Copyright DrugLib.com, 2006-2017