DrugLib.com — Drug Information Portal

Rx drug information, pharmaceutical research, clinical trials, news, and more

Isovue (Iopamidol Intravascular) - Published Studies

 
 



Isovue Related Published Studies

Well-designed clinical trials related to Isovue (Iopamidol Intravascular)

Comparative investigation of i.v. iohexol and iopamidol: effect on renal function in low-risk outpatients undergoing CT. [2012]

Correlative study of indirect computed tomography lymphography using iopamidol and histopathology in a cervical lymph node metastasis model. [2011.04]

Comparison of a low-osmolar contrast medium, iopamidol, and an iso-osmolar contrast medium, iodixanol, in MDCT coronary angiography. [2010.11]

Nephrotoxicity of iodixanol versus iopamidol in patients with chronic kidney disease and diabetes mellitus undergoing coronary angiographic procedures. [2009.11]

Well-designed clinical trials possibly related to Isovue (Iopamidol Intravascular)

Multicenter comparison of high concentration contrast agent iomeprol-400 with iso-osmolar iodixanol-320: contrast enhancement and heart rate variation in coronary dual-source computed tomographic angiography. [2011.07]

Comparison of the effect of low- and iso-osmolar contrast agents on heart rate during chest CT angiography: results of a prospective randomized multicenter study. [2011.03]

Embolization of the gastroduodenal artery before selective internal radiotherapy: a prospectively randomized trial comparing standard pushable coils with fibered interlock detachable coils. [2011.02]

Image quality and attenuation values of multidetector CT coronary angiography using high iodine-concentration contrast material: a comparison of the use of iopromide 370 and iomeprol 400. [2010.11]

Heart rate variability and heat sensation during CT coronary angiography: Low-osmolar versus iso-osmolar contrast media. [2010.09]

Prospective study comparing two iodine concentrations for multidetector computed tomography of the pancreas. [2010.09]

Reduction of contrast material volume in 3D angiography of the brain using MDCT. [2010.08]

Are there any differences in acute adverse reactions among five low-osmolar non-ionic iodinated contrast media? [2010.07]

Prospective randomized comparison of chemoembolization with doxorubicin-eluting beads and bland embolization with BeadBlock for hepatocellular carcinoma. [2010.06]

Contrast material injection protocol with the dose adjusted to the body surface area for MDCT aortography. [2010.04]

64-Slice CT angiography of the abdominal aorta and abdominal arteries: comparison of the diagnostic efficacy of iobitridol 350 mgI/ml versus iomeprol 400 mgI/ml in a prospective, randomised, double-blind multi-centre trial. [2010.03]

Contrast-induced acute kidney injury in patients with renal dysfunction undergoing a coronary procedure and receiving non-ionic low-osmolar versus iso-osmolar contrast media. [2010.01]

Reduction of the total injection volume of contrast material with a short injection duration in 64-detector row CT coronary angiography. [2010.01]

Unexpected changes in clinical diagnosis: early abdomino-pelvic computed tomography compared with clinical evaluation. [2009.11]

Choice of contrast medium in patients with impaired renal function undergoing percutaneous coronary intervention. [2009.10]

Depiction of hypervascular hepatocellular carcinoma with 64-MDCT: comparison of moderate- and high-concentration contrast material with and without saline flush. [2009.09]

Contrast-induced nephropathy and long-term adverse events: cause and effect? [2009.07]

Optimization of scan delay for routine abdominal 64-slice CT with body weight-adapted application of contrast material. [2009.07]

MDCT angiography for detection of pulmonary emboli: comparison between equi-iodine doses of iomeprol 400 mgI/mL and iodixanol 320 mgI/mL. [2009.06]

Renal protective effects and the prevention of contrast-induced nephropathy by atrial natriuretic peptide. [2009.03.24]

Enhancement and safety of iomeprol-400 and iodixanol-320 in patients undergoing abdominal multidetector CT. [2009.03]

Nephrotoxicity of iso-osmolar iodixanol compared with nonionic low-osmolar contrast media: meta-analysis of randomized controlled trials. [2009.01]

Is treatment with N-acetylcysteine to prevent contrast-induced nephropathy when using bicarbonate hydration out of date? [2008.12]

Functional cardiac CT imaging: a new contrast application strategy for a better visualization of the cardiac chambers. [2008.12]

Demonstration of the Adamkiewicz artery in patients with descending or thoracoabdominal aortic aneurysm: optimization of contrast-medium application for 64-detector-row CT angiography. [2008.11]

Bolus injection of contrast agents with various iodine concentrations and delivery rates for intracranial three-dimensional CT angiography: evaluation of intracranial arteriovenous contrast using a multidetector-row CT scanner. [2008.10]

Sodium bicarbonate vs sodium chloride for the prevention of contrast medium-induced nephropathy in patients undergoing coronary angiography: a randomized trial. [2008.09.03]

Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: assessment of image quality, stenosis, and radiation dose. [2008.08]

Optimal contrast dose for depiction of hypervascular hepatocellular carcinoma at dynamic CT using 64-MDCT. [2008.04]

Improved estimation of glomerular filtration rate by serum cystatin C in preventing contrast induced nephropathy by N-acetylcysteine or zinc--preliminary results. [2008.04]

The ACTIVE Trial: comparison of the effects on renal function of iomeprol-400 and iodixanol-320 in patients with chronic kidney disease undergoing abdominal computed tomography. [2008.03]

Quantitative assessment of blood volume, blood flow, and permeability of the brain of clinically normal dogs by use of dynamic contrast-enhanced computed tomography. [2008.01]

Comparison of 2 contrast materials with different iodine concentrations in 3-dimensional computed tomography angiography of the hepatic artery at multi-detector-row computed tomography: a randomized study. [2007.11]

Comparison of usefulness of sodium bicarbonate versus sodium chloride to prevent contrast-induced nephropathy in patients undergoing an emergent coronary procedure. [2007.09.01]

Focused helical CT using rectal contrast material only as the preferred technique for the diagnosis of suspected acute appendicitis: a prospective, randomized, controlled study comparing three different techniques. [2007.08]

Cardiac Angiography in Renally Impaired Patients (CARE) study: a randomized double-blind trial of contrast-induced nephropathy in patients with chronic kidney disease. [2007.06.26]

Effects of non-ionic iodinated contrast media on patient heart rate and pressures during intra-cardiac or intra-arterial injection. [2007.06.12]

Hypervascular hepatocellular carcinomas: bolus tracking with a 40-detector CT scanner to time arterial phase imaging. [2007.04]

Coronary angiography by 64-detector row computed tomography using low dose of contrast material with saline chaser: influence of total injection volume on vessel attenuation. [2007.03]

Image quality in CT perfusion imaging of the brain. The role of iodine concentration. [2007.01]

Prediction of aortic peak enhancement in monophasic contrast injection protocols at multidetector CT: phantom and patient studies. [2007.01]

Comparison of enhancement, image quality, cost, and adverse reactions using 2 different contrast medium concentrations for routine chest CT on 16-slice MDCT. [2006.09]

Prophylaxis of contrast material-induced nephropathy in patients in intensive care: acetylcysteine, theophylline, or both? A randomized study. [2006.06]

Contrast bolus optimization for cardiac 16-slice computed tomography: comparison of contrast medium formulations containing 300 and 400 milligrams of iodine per milliliter. [2006.05]

The role of N-acetylcysteine in the prevention of contrast-induced nephrotoxicity. [2006.05]

Effect of saline pushing after contrast material injection in abdominal multidetector computed tomography with the use of different iodine concentrations. [2006.03]

High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography: iopromide 370 versus iomeprol 400. [2006.03]

Comparative study of vascular enhancement on post-contrast CT using three dosages of iodinated contrast media for the aim of detecting brain metastasis in patients with lung cancer. [2006.02]

Variation of the time to aortic enhancement of fixed-duration versus fixed-rate injection protocols. [2006.01]

Low-dose multidetector-row CT angiography of the infra-renal aorta and lower extremity vessels: image quality and diagnostic accuracy in comparison with standard DSA. [2006.01]

Intravenous contrast material administration at helical 16-detector row CT coronary angiography: effect of iodine concentration on vascular attenuation. [2005.08]

Does iodine concentration affect the diagnostic efficacy of biphasic spiral CT in patients with hepatocellular carcinoma? [2005.05]

Multiphase contrast-enhanced CT of the liver with a multislice CT scanner: effects of iodine concentration and delivery rate. [2005.02]

Other research related to Isovue (Iopamidol Intravascular)

Less iodine injected for the same diagnostic performances: comparison of two low-osmolar contrast agents (iobitridol 350 and iopamidol 370) in coronary angiography and ventriculography: a randomized double-blind clinical study. [2010.08]

Permanent hearing loss with iopamidol following aortic angiography in a hemodialysis patient: a case report and review of the literature. [2010.04]

A new approach to percutaneous transhepatic portal embolization using ethanolamine oleate iopamidol. [2010.02]

Incidence of seizures associated with iopamidol or iomeprol myelography in dogs with intervertebral disk disease: 161 cases (2000-2002). [2009.12]

Assessment of renal vasoconstriction in vivo after intra-arterial administration of the isosmotic contrast medium iodixanol compared to the low-osmotic contrast medium iopamidol. [2009.05]

Iopamidol enema treatment for meconium obstruction of prematurity in extremely low-birth weight infants: a safe and effective method. [2009.03]

A comparison of the efficacy and safety of iopamidol-370 and iodixanol-320 in patients undergoing multidetector-row computed tomography. [2007.12]

A prospective randomised controlled trial to determine the early and late reactions after the use of iopamidol 340 (Niopamtrade mark) and iomeprol 350 (Iomeron((R))) in cardiac catheterisation. [2007.02]

Contrast-induced nephropathy in patients with chronic kidney disease undergoing computed tomography: a double-blind comparison of iodixanol and iopamidol. [2006.11]

Iopamidol myelography-induced seizures. [2005.04.11]

Other possibly related research studies

Evaluation of the acute adverse reaction of contrast medium with high and moderate iodine concentration in patients undergoing computed tomography. [2006.12]

Multidetector CT in abdominal aortic aneurysm treated with endovascular repair: are unenhanced and delayed phase enhanced images effective for endoleak detection? [2006.12]

Sympathetic skin response: monitoring of CT-guided lumbar sympathetic blocks. [2006.11]

Factors contributing to blood-brain barrier disruption following intracarotid injection of nonionic iodinated contrast medium for cerebral angiography: experimental study in rabbits. [2006.06]

Spectral coronary multidetector computed tomography angiography: dual benefit by facilitating plaque characterization and enhancing lumen depiction. [2006.09]

Signal flare phenomenon as active bleeding in retroperitoneal hematoma with hematocrit effect on dynamic CT scan: three clinical cases and experimental study based on a specific gravity theory. [2006.09]

Preoperative MDCT evaluation of the artery of Adamkiewicz and its origin. [2006.09]

[Clinical impact of nephropathy induced by contrast medium in patients with acute myocardial infarction undergoing emergent coronary angiography] [2006.07]

Contrast media and nephropathy: findings from systematic analysis and Food and Drug Administration reports of adverse effects. [2006.08]

Quantitative imaging of microvascular permeability in a rat model of lipopolysaccharide-induced sepsis: evaluation using cryostatic micro-computed tomography. [2006.08]

Intracranial aneurysm stenting: follow-up with MR angiography. [2006.08]

A novel contrast removal system from the coronary sinus using an adsorbing column during coronary angiography in a porcine model. [2006.05.02]

Drug eruptions to contrast media in Japan. [2006.05]

Multidetector CT with double arterial phase and high-iodine-concentration contrast agent in the detection of hepatocellular carcinoma. [2006.03]

Follow-up of intracranial aneurysms selectively treated with coils: Prospective evaluation of contrast-enhanced MR angiography. [2006.04]

Dynamic contrast-enhanced MDCT of the liver: analysis of the effect of different iodine concentrations with the same total iodine dose in the same chronic liver disease patients. [2005.12]

CT lymphography-navigated sentinel lymph node biopsy in patients with superficial esophageal cancer. [2006.02]

Renal function and cardiac angiography. [2006.01]

Cerebral air embolism during imaging of a sentinel lymphatic drainage in the respiratory tract. [2006.02]

MDCT appearance of gastrointestinal stromal tumors after therapy with imatinib mesylate. [2006.02]

16-MDCT aortography with a low-dose contrast material protocol. [2006.02]

Troponin I as a marker of doxorubicin induced cardiotoxicity. [2005]

Optimal scanning protocol of multislice CT virtual intravascular endoscopy in pre-aortic stent grafting: in vitro phantom study. [2006.05]

Sclerotherapy for venous malformations using a "negative subtraction" technique. [2006.02]

Integrated PET/CT and the dry pleural dissemination of peripheral adenocarcinoma of the lung: diagnostic implications. [2006.01]

Prolonged survival of Fischer rats bearing F98 glioma after iodine-enhanced synchrotron stereotactic radiotherapy. [2006.02.01]

[16-row multidetector CT angiography of the aortoiliac system and lower extremity arteries: contrast enhancement and image quality using a standarized examination protocol] [2005.11]

Small-bowel obstruction: coronal reformations from isotropic voxels at 16-section multi-detector row CT. [2006.01]

Basal cell adenoma of the parotid gland: characteristics of 2-phase helical computed tomography and magnetic resonance imaging. [2005.11]

Benign or malignant?: differentiating breast lesions with computed tomography attenuation values on dynamic computed tomography mammography. [2005.11]

Demonstration of cardiac involvement of sarcoidosis by contrast-enhanced multislice computed tomography and delayed-enhanced magnetic resonance imaging. [2005.11]

Solitary pulmonary nodule: characterization with combined wash-in and washout features at dynamic multi-detector row CT. [2005.11]

Thin-section multiplanar reformats from multidetector-row CT data: utility for assessment of regional tumor extent in non-small cell lung cancer. [2005.10]

Intravenous injection of high and medium concentrations of computed tomography contrast media and related heat sensation, local pain, and adverse reactions. [2005.09]

-- advertisement -- The American Red Cross
 
Home | About Us | Contact Us | Site usage policy | Privacy policy

All Rights reserved - Copyright DrugLib.com, 2006-2017