DrugLib.com — Drug Information Portal

Rx drug information, pharmaceutical research, clinical trials, news, and more



Comparison of EUS-Guided Fine Needle Aspiration Technique

Information source: Asan Medical Center
ClinicalTrials.gov processed this data on August 23, 2015
Link to the current ClinicalTrials.gov record.

Condition(s) targeted: EUS-FNA; Cytodiagnosis

Intervention: EUS-FNA (Procedure); Echoendoscope Olympus GF-UCT240 (Device)

Phase: N/A

Status: Recruiting

Sponsored by: Asan Medical Center

Official(s) and/or principal investigator(s):
Do Hyun Park, MD, PhD, Principal Investigator, Affiliation: University of Ulsan College of Medicine, Asan Medical Center

Summary

EUS-guided fine needle aspiration (EUS-FNA) is a safe and effective method for diagnosing pancreatic and peripancreatic solid masses. The aim of this study is to compare the two aspiration methods in EUS-FNA: negative-pressure suction with syringe vs. capillary sampling with stylet slow-pull technique. We will evaluate the diagnostic adequacy and accuracy of the specimens obtained by EUS-FNA with two aspiration methods.

Clinical Details

Official title: Comparison of EUS-guided Fine Needle Aspiration Technique: Negative-pressure Suction With Syringe vs. Capillary Sampling With Stylet Slow-pull Technique

Study design: Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Crossover Assignment, Masking: Single Blind (Outcomes Assessor), Primary Purpose: Diagnostic

Primary outcome: Rate of true positive or true negative results in pathology

Detailed description: EUS-guided fine needle aspiration (EUS-FNA) is a safe and effective method for diagnosing pancreatic and peripancreatic solid masses. The diagnostic accuracy of EUS-FNA has been reported to be 62-96%. There are two aspiration methods for obtaining specimens with EUS needle, application of a negative-pressure syringe and capillary sampling (without suction). The former method is thought to increase cellularity of obtained specimen. However, a negative-pressure syringe can worsen the specimen quality by increasing the amount of bloody material in the specimen and damaging the tissue. Blood in the aspirate dilutes the sample and makes direct smears more difficult to interpret because clots form. Meanwhile, the latter method might yield a small sample with a high diagnostic yield because of a decreased amount of sanguineous staining. Recently, EUS-guided fine needle biopsy with 22-gauge ProCore needle using capillary sampling while removing the stylet slowly for 40 sec during the to-and-fro movement of the needle (capillary sampling with style slow-pull technique) for pancreas biopsy was reported to provide significantly higher tissue adequacy compared to half- (5 mL) or full suction (10 mL) methods in animal study. Therefore, we will perform the prospective randomized clinical trial comparing the diagnostic adequacy and accuracy of the specimens obtained by two different aspiration methods in EUS-FNA: negative-pressure suction with syringe (NPS) vs. capillary sampling with stylet slow-pull technique (CSS). The primary end point of this study is to evaluate the difference of diagnostic accuracy between two aspiration methods. This study is a prospective randomized clinical trial. The needle used in this study is a conventional EUS-FNA needle (Echotip, Cook Medical, Winston-Salem, NC) approved by the FDA and Korea Food and Drug Administration (KFDA). The procedure will be performed by one endoscopist. The patients will undergo EUS-FNA under conscious sedation with midazolam and meperidine. The procedure is same as conventional EUS-FNA except the aspiration method. The first aspiration method (NPS or CSS) will be assigned by random number table. After first needle passage, the next EUS-FNA will be done by different aspiration method. A total of four times of needle passes will be performed in each patient with alternative aspiration methods (i. e., NPS and CSS each two times in one patient). Sample size 1. We Assumed that the diagnostic accuracy of two aspiration methods (NPS and CSS) are equivalent (88%) and the non-inferiority margin is 10%. 2. A two-tailed sample size calculation was performed with 1% alpha error to attain 80% power. Using a 10% dropout rate, the target sample size was 51 (i. e., NPS and CSS each 102 times in 51 patients). Statistical analyses

1. Chi-square test - Comparing the specimen adequacy of 1st needle pass according to the

aspiration methods.

2. Student's t-test - Number of needle passes for optimal specimen and for accurate

diagnosis.

3. McNemar test - Comparing the diagnostic yields according to the aspiration methods.

4. Sensitivity, specificity, accuracy, positive and negative predictive values.

Eligibility

Minimum age: 20 Years. Maximum age: N/A. Gender(s): Both.

Criteria:

Inclusion Criteria:

- The patients with pancreatic solid mass which requires EUS-FNA for diagnosis

- Informed consent is obtained

Exclusion Criteria:

- Age < 20 years

- Active gastrointestinal bleeding

- Bleeding tendency (platelet < 50,000/mm3 and/or PT INR > 1. 5)

- Unable to understand and/or read the informed consent.

Locations and Contacts

Asan Medical Center, Seoul 138-736, Korea, Republic of; Recruiting
Do Hyun Park, MD, PhD, Phone: +82230103194, Email: dhpark@amc.seoul.kr
Additional Information

Starting date: June 2013
Last updated: August 15, 2013

Page last updated: August 23, 2015